Call Toll Free: (888) 886-8185
8AM - 5PM PST

 

Solutions for the Industrial Market
www.solutionsdirectonline.com

Home About Us Products Contact Us My Account
   Advanced Search
Enclosures
bullet-point Fiberglass Enclosures
bullet-point Metal Enclosures
bullet-point Polycarbonate Enclosures
bullet-point Thermal Management
bullet-point Racks & Rack Cabinets
bullet-point Wiring Duct & Tubing
Infrared Temperature Measurement Products
bullet-point Fixed-Mount Infrared Temperature Sensors
bullet-point Infrared Cameras & Windows
Machine Components
bullet-point Adjustable Levers
bullet-point Leveling Mounts
bullet-point Pull Handles & Access Hardware
Process Control & Measurement
bullet-point Pressure
bullet-point Temperature
bullet-point Process Control
Scales and Balances
bullet-point Analytical Balances
bullet-point Moisture Analyzers
bullet-point Precision Balances
bullet-point Portable Balances
bullet-point Mechanical Balances
Audible & Visual Signals
Material Testing Equipment
Technical Specifications
bullet-point Fiberglass Enclosures
bullet-point Metal Enclosures
bullet-point ABS/Polycarbonate Enclosures
bullet-point Infrared Temperature Sensors
bullet-point Test Sieves
bullet-point Thermal Management
Customer Support
bullet-point Ordering Information
bullet-point Terms & Conditions
bullet-point Return Policy
bullet-point Press Releases
Connect with Us
Solutions-Direct-Facebook Solutions-Direct-Twitter Solutions-Direct-LinkedIn Solutions-Direct-Google+

Enclosure Air Conditioners, Fans, & Heaters Technical Specifications


With wide spread use of micro-electronics in today's control systems, temperature mangement takes on a new priority in order to ensure steady and reliable performance. The maintenance of a correct operating temperature may combine both cooling and/or heating inside an enclosure which can protect against costly down time and system failures. Before selecting an air conditioner, fan, or heater it is necessary to understand the cooling or heating capacity that your enclosure requires.

Click here to Shop Now or if you have any questions and need assistance choosing an enclosure air conditioner, fan, or heater for your application please contact us at (888) 886-8185.

Click here to download Climate Control Sizing Software for either cooling or heating of electrical/electronic enclosures.
(Requires Java. Download it here.)

Click here for a cooling calculation guide.

Click here for a heater calculation guide.


Thermal Management - General Selection Consideration
Thermal Management - Glossary of Thermal Management Terminology
Thermal Management - Sizing an Air Conditioner
Thermal Management - General Specifications of Blowers and Fans
Thermal Management - Sizing Blowers and Fans
Thermal Management - General Information on Heating Products
Thermal Management - Heater Sizing Information


General Selection Condiseration

(Return to Top)

Cooling
Conditions Solution Advantages Disadvantages
Maximum desired enclosure temperature is 10°F or 5°C above maximum outside ambient.
Oversize the enclosure.Easy to implement, no maintenance. Maintains NEMA rating of the enclosure.Dissipates small amount of heat. Larger enclosure size takes up more space.

Install ventillation louvers.Economical solution, very little maintenance, easy to implement.Dissipates small amount of heat. Larger enclosure size takes up more space.

Install filter fans.Easy to implement, no maintenance. Maintains NEMA rating of the enclosure.Dissipates small amount of heat. Larger enclosure size takes up more space.

Use an air/air heat exchanger.Easy to implement, no maintenance. Maintains NEMA rating of the enclosure.Dissipates small amount of heat. Larger enclosure size takes up more space.

Maximum desired enclosure temperature lower than maximum outside ambient. Use an air conditioner. Easy to install. Temperature control via factory installed thermostat. Removes large amounts of heat. Maintains NEMA rating of enclosure, dehumidifies enclosure air. Must maintain filter. Generally not to be used when outside temperature is below 59°F (15°C) or above 130°F (52°C).


Circulation
Conditions Solution Advantages Disadvantages
Localized heat or 'hot spots'. Install circulation fans in the enclosure. Economical solution, no maintenance, easy to install, Maintains NEMA rating of the enclosure. Dissipates small amount of heat.


Heating
Conditions Solution Advantages Disadvantages
Outside temperature is below minimum allowable equipment operation range. Heat with radiant heater. Economical power consumption. Reliable, can be temperature controlled. Consumes energy, takes up internal panel space.

Condensation occurs. Heat with radiant heater to maintain temperature above the dew point. Economical power consmpution. Reliable, humidity can be controlled. Consumes energy, takes up internal panel space.




Glossary of Thermal Management Terminology

(Return to Top)

Construction: Outer shell of sheet steel.

Closed Loop Cooling: Ambient outside air is never mixed with clean dry enclosure air.

Operating Temperature: Minimum +46°F (+8°C). Maximum +125°F (+52°C).

Gasketing: Is provided and/or installed on all units to maintain NEMA ratings specified.

Templates: Provided on all units for easy layout of cutouts and mounting.

Power: Available in 115 V 60 Hz, 110 V 50 Hz and 230 V, 460 50/60Hz 3 phase.

Filter: Removable filter mat made from synthetic fibers are reusable and can be rinsed clean.

Refrigerants: All models use environmentally friendly R134a.

Fans: All blower motors are thermal protected and sealed with permanent lubricants.

Condensate Disposal: Built in condensate evaporators are standard on most models. All units feature a condensate drain fitting complete with hose attachment.

Insulation: Cold components, lines and evaporator compartment insulated for maximum efficiency and protection against condensation.

Quality Assurance: Prior to charging, the refrigeration system is hermetically sealed with all joints brazed under protection gas atmosphere to exclude any internal scale. After a thorough leak test every unit undergoes safety and function checks, then is serialized and packed into sturdy boxes prior to shipment.

Installation Manuals: Included with all models are detail drawings, mounting, schematic and wiring diagrams, a trouble shooting checklist and warranty information.



Sizing an Air Conditioner

(Return to Top)

The proper selection of an air conditioner is determined by the following steps:

Step 1 - Internal heat load quoted as Watts that must be dissipated.
Step 2 - The exposed surface area of the enclosure.
Step 3 - Temperature differential required between maximum inside temperature and maximum outside ambient.
Step 4 - Final calculation of the above.

Step One






















1 Watt = 3.413 BTU/H

Determine the internal heat load (in Watts) that must be dissipated.
Step Two






















1 m = 10.76 ft

Calculate the exposed surface area of the enclosure:

[2(h"xw") + 2(h"xd") + (w"xd")]*(1/144) = Area (ft)

(Example for freestanding enclosure)

Step Three






















1°C or 1°KΔT=1.8°FΔT

Determine the temperature differential by subtracting the maximum allowable temperature inside the enclosure (Ti) from the maximum ambient temperature outside the enclosure (To).

To-Ti = DT
Step Four

(Watts x 3.413)     +     [1.25 x Area (ft)     x     DT (°F)]   =   BTU/H
Capacity Required BTU/H (Capacity Rating of Air Conditioner)



The DTS/DTT offering is available in the most popular selection of cooling capacities, sizes, voltages, and mounting configurations. Available capacities range form 1,200 to 12,000 BTU/H in both side mounting and top mounting models. All models use powerful radial fans for maximum air circulation inside the enclosure in ambient temperature of 125°F (+52°C). Models from 2,000 BTU/H capacity are equipped with thermal expansion valves for optimal use of the evaporator heat exchange surface under all operating conditions. For additional protection of the compressor motor, these valves are supplied as standard with Maximum Operating Pressure control devices (MOP). For energy conservation, the use of hot gas bypass valves is limited to the unload starting and control of large compressors from 8,000 BTU/H upwards. All air conditioners were developed, designed, and subject to final inspections in accordance with international standards.


General Specifications of Blowers and Fans

(Return to Top)

Blowers and fans use forced convection cooling, which means ambient air flows through a filter into the enclosure to cool heated components. Both blowers and fans are sized in CFM (cubic feet per minute).

It is recommended that an exhaust filter be used in combination with the blower or filter fan to act both as an exhaust point for the hot internal air plus aid in the pressurization of the enclosure, reducing the chance of unfiltered air entering the enclosure. Whenever possible, the blower or filter fan should be located in the bottom third of the enclosure and the filtered exhaust grill placed as high as possible on the opposing side. Performance levels can be further increased by adding a second exhaust filter.


Sizing Blowers and Fans

(Return to Top)

To determine the CFM (cubic feet per minute) required in any standard situation, use the following calculation, (non-standard situations would consist of high air density - significantly more then 0.075 lbs per cubic feet).


Note: The calculation above is exact, but adding an additional 25% to the CFM level is a standard safety factor.

If the air density is high (significantly more then 0.075 lbs per cubic foot), use the number calculated above in the following formula:


Note: Ambient Temperature must be lower than maximum internal temperature for fan/blower to be effective.


General Information on Heating Products

(Return to Top)

Heating products protect electronic and electrical components from temperature problems that are below acceptable tolerances. There are obvious circumstances when extremely low ambient (outside cabinet) temperatures would require a heater, but there are also less apparent times that a heater should be considered. For example, a system may run all day having its components generate heat, but once the system shuts down for the night, the quick drop in temperature could cause condensation and possibly corrosion - a heater could maintain a safe, constant temperature.

Some components today are sensitive enough that both cooling and heating could be required in the same enclosure. When designing your system, be aware of the need to maintain a relatively constant temperature inside the enclosure as ambient temperatures swing from cool to very hot. Hammond thermostats (one for heaters and one for cooling products) can control both systems automatically.



Heater Sizing Information

(Return to Top)

PH = Total power required for this Application (W)

PV = Existing power from components (W)

DT = Temperature differential (Kelvin) ambient to cabinet interior (1°Kelvin = 1°C = 1.8°F)

A = Free-standing cabinet surface area (ft)

k = Heat transmission coefficient (W/ftK) convection in quiet air:
  • Painted Steel - approx. 0.51 W/ftK
  • Aluminum - approx. 1.115 W/ftK
  • Plastic - approx. 0.325 W/ft
  • Stainless Steel - approx. 0.344 W/ftK
Formula
PH = (DT x k x A) - PV
If enclosure located outside, use x 2 (DT x k x A)


Sample with Solution

DT = 5 Kelvin

k = 0.51 W/ftK (Painted Steel)

A = 50 ft

PV = 50 Watts

PH = F(5 x 0.51 x 50) - 50

      = 127.5 - 50

      = 77.5 Watts


Recommendation: 80 Watt Capacity Heater